We have located the source of the power loss at the gfci protection underneath the deck at grill location. Inside the cable box is another GFCI, this is built into the cord. We recommend having surge protection installed.


Nicholas T.

Nicholas T. Job Checkin

Run three new dedicated circuits into the unfinished closet in the basement bathroom. We will install two new receptacles one for the water heater as well as one for the sump pump. The third circuit will be ran to a junction box to feed the basement bathroom lights.


dennis@haasandsons.com

dennis@haasandsons.com Job Checkin

Recommend replacement of breakers in both panels due to water damage and corrosion build up. Installation of GFCI in bathroom on first floor due to device not working properly. Replacement of burnt out receptacle on panel with a GFCI as per code. Recommend panel service to correct improper screws that mount panel cover on and eliminate “machine pointed” screws.


Matt M.

Matt M. Job Checkin

Replace outdoor receptacle and cover with gfci and bubble cover


Michael W.

Michael W. Job Checkin

We have repaired the garage receptacle and lighting circuit. We located a fault in the wiring leading down the wall and possibly outside. Switch was located behind built shelving in garage. In addition we have replace the switches and the garage door receptacle, ensuring proper splicing and terminations. Garage power restored. Switch has been removed and blanked off where fault was.


William M.

William M. Job Checkin

Customer called with heat pump breaker tripping. Upon further tested we decided it would be best to replace the breaker as the heat pump was already tested and confirmed to work. Therefore I added a new 30A breaker for outdoor heat pump. Also I converted 3 fixtures to LED. One 4 ft and two 2ft. And, lastly I will be adding 2 whole home surge protectors. .


Larry B.

Larry B. Job Checkin

Installed a 20 amp dedicated circuit in garage.

Installed a 20 amp dedicated circuit in garage.